Top Tips

When to Replace your Lab Balance

At Precisa, we understand that needing to replace your lab balance can be an inconvenient, costly and daunting prospect. That’s why we have put together this handy guide to help you figure out if your balance really needs replacing, how to look after your balance and how to choose a new balance to meet all of your needs.
Top Tips

Precisa’s Guide to Balance and Scale Calibration

In part two of our series on balance calibration, and the importance of our UKAS balance and scale calibration services, we now explore the specific details of the process.
Top Tips

Top 5 Reasons why Precisa is the Best Balance Company for your Precision Weighing

We want to help you find the right balance company to meet your needs, but we also know being in the marketplace for new precision balances can be tricky. If you have weighed up all of your options and still can’t make a decision – we’re here for you.
Top Tips

IP65 Connection

At Precisa our IP65 is ideal for peripheral devices such as secondary display. Here you will find a handy step by step guide on how to connect your IP65.
Top Tips

A Guide to Weighing Balance Accuracy

Our analytical balances have 0.1mg readability, 4 place or 0.0001g readability balances with capacities up to 520g with or without internal calibration.
Top Tips

Balance Readability - What is the Readability of My Balance?

If you have a readability interval of d=0.0001g, it means that the smallest step you can read on it is 0.0001g (or 0.1mg) and increasing or decreasing the weight applied will change.
Top Tips

How to Determine the Right Tolerance and Class for the Check Weights

Using the information from above you have determined the Weight Class requirement for your check weights. You can now decide which weight(s) from that class are required to monitor the performance of your balance.
Top Tips

Scale Calibration: Level-Up Your Balance – Correct Balance Installation Guide

The principle is the same as that of a spirit level. The ideal position of the bubble is dead centre of the circle. This will give the balance its correct conditions for proper functionality. Its position should be relative to the circle as this will inform your next step.
Top Tips

Reduce Time and Costs with Precisa’s prepASH Thermogravimetric Analyser

Qualified laboratory staff are often overworked in the lab and frequently several analysis systems have to be operated at the same time with analysis protocols provided and results evaluated. The target objective must be to simplify this procedure by offering a less complex and time-consuming solution that reduces overall costs.
Top Tips

Using the Lab Balance Model Number to Calculate Capacity and Readability

For Dual or Floating Range balances it is worth investigating the supporting text or directly contacting Precisa to find out the upper limits of the first range to ensure that it meets you requirements and that you do not lose accuracy as you move between the ranges.